COMMON SPECIFICATIONS Accuracy: ±0.005% rdg Span Temperature Coefficient: ±20 ppm Step Response: 1 sec to 99.9% Warmup to Rated Accuracy: 50 min Operating Ambient: 0 to 50°C, 95%RH, non-condensing Storage Ambient: -40 to 85°C Power: 230 Vac, 49-400 Hz; 10 to 32 Vdc Power Consumption: 6 W nominal, 10 W max Normal Mode Rejection: 60 dB Common Mode Rejection: 120 dB Common Mode Voltage: 1500 V peak per HV test Resolution: 15-bit Conversion: dual-slope technique Reading Rate: 3/sec or 13/sec, 60 Hz; 3/sec or 12/sec, 50 Hz Display: red or green 6-digit, 14-segment, 13.7 mm (0.54"); 4 alarm indicators Dimensions: 48 H x 96 W x 165 mm D (1.9" x 3.8" x 6.5") Panel Cutout: 45 H x 92 mm W (1.8" x 3.6"); 1/8 DIN Weight: 574 g (1.27 lb) TTL Outputs: four, isolated open collector; rated 150 mA at 1 V sink, 30 V open BCD Output: isolated, tri-state, TTL/CMOS compatible; external 5 V supply for isolated; internal 5 V supply for non-isolated Dual Relays: form C, 7 A at 30 Vdc or 230 Vac Four Relay Option: dual 7 A relays and dual 1 A relays Analog Output 0-5 V/1-5 V/0-10 V/ 0-20 mA/4-20 mA, user selectable; 354 Vp isolation; 14-bit resolution; 0.1% accuracy, 50 msec step response RS-232 Communications 300/600/1200/2400/4800/9600/19.2k baud; RJ11 4-wire connection; complete program setup and message display capability; programmable to transmit current display, alarm status, min/max, actual measured input value and status RS-485 Communications 300/600/1200/2400/4800/9600/19.2k baud; RJ12 6-wire connection; addressable from 0 to 199 PROCESS INPUTS—INFXU, INFXP, INFXS, INFXW Voltage Input Ranges: 0-100 mV, 0-1 V, 0-5 V, 1-5 V, 0-10 V, 0-100 V, ±50 mV, ±500 mV, ±5 V, ±50 V Current Input Ranges: 0-20 mA, 4-20 mA Input Configuration: single-ended Polarity: Unipolar/bipolar, programmable Span Adjustment: 0.00001 to 500,000; programmable Offset Adjustment: 0 to 999,999 or 0 to -99,999; programmable TEMPERATURE INPUTS—INFXU, INFXT Thermocouple Input Types: J, K, T, E, R, S, B, N, J DIN RTD Input: any 6 to 6k ohm NIST or DIN platinum and any linear RTD RTD Connection: 2, 3 or 4 wire Sensor Break Protection: upscale or downscale, programmable Overvoltage Protection: 25 V peak SENSOR EXCITATION—INFXP, INFXS, INFXU, INFXW Sensor Excitation, INFXS, INFXU, INFXW: 10 V to 30 mA; 24 V to 25 mA Sensor Excitation, INFXP: 24 V to 25 mA
* Specify C (Celsius), F (Fahrenheit) or K (Kelvin)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Copyright 2003,
NEWPORT Electronics, Inc. All rights reserved.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||